2.9 Change the Drive Enclosure Type
YASKAWA ELECTRIC
SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
65
A - Front of drive
B - Screw holes on bottom
Figure 2.60 Locations of Screw Holes on Bottom
3.
Align the screw holes on conduit bracket 2 with the screw holes on conduit bracket 1.
Tighten the screws to a tightening torque of 0.98 N
∙
m to 1.33 N
∙
m (8.67 lb.
∙
in. to 11.77 lb.
∙
in.).
A - Conduit bracket 2
Figure 2.61 Attach Conduit Bracket 2
◆
Attach the Protective Cover (Procedure F)
■
Attach the Top Protective Cover
Align the screw holes of the top protective cover with the screw holes on the top of the drive.
Tighten the screws to a tightening torque of 0.98 N∙m to 1.33 N∙m (8.67 lb.∙in. to 11.77 lb.∙in.) to attach the cover.
Figure 2.62 Attach the Top Protective Cover