ELEC
SIGNAL SYSTEM
Check the connection of the entire signal
system.
Refer to “CIRCUIT DIAGRAM” Page no 7-14.
1. BULB AND BULB SOCKET
• Check the bulb and bulb socket for conti-
nuity.
2. NEUTRAL SWITCH
• Disconnect the neutral switch lead.
• Check the continuity between the switch
terminal and ground.
D. If the neutral indicator lights fails to
operate.
Replace the Bulb and/or Bulb Socket
NO CONTINUITY
CONTINUITY
Replace the Neutral switch.
NO CONTINUITY
3. VOLTAGE
• Connect the Multimeter (DC20 V) to the
neutral switch lead
• Turn the main switch to on position.
• Select the gear position in neutral.
• Check for voltage (12 V) on the “Brown” ter-
minal on the “Neutral Bulb” and body earth
(“Sky Blue” wire)
Multimeter (+) lead Ÿ Sky Blue Terminal ¿
Multimeter (-) lead Ÿ Body Earth À
OUT OF SPECIFICATION
This circuit is O.K.
CONTINUITY
MEETS
SPECIFICATION
7-20