8-43
6. Thermo unit
S
Remove the thermo unit from the radiator.
S
Connect the pocket tester (
Ω
10) to the ther-
mo unit
.
S
Immerse the thermo unit in the water
.
S
Measure the resistance.
Thermo unit resistance:
80
_
C: 47
X
53
Ω
100
_
C: 26
X
30
Ω
Replace thermo unit.
BAD CONDITION
7. Wiring connection
Check the entire cooling system for connec-
tions. Refer to “CIRCUIT DIAGRAM”.
Correct.
POOR CONNECTION
CORRECT
:
GOOD
CONDITION
1
2
WARNING
S
Handle the thermo unit with special care.
S
Never subject it to strong shock or allow it
to be dropped. Should it be dropped, it
must be replaced.
Replace the temperature meter.
COOLING SYSTEM
ELEC
Summary of Contents for 4TX-AE1
Page 1: ......
Page 2: ......
Page 8: ......
Page 9: ...GEN INFO 1 ...
Page 11: ...GEN INFO ...
Page 20: ...SPEC 2 ...
Page 22: ...SPEC ...
Page 45: ...2 23 LUBRICATION DIAGRAMS SPEC 1 Cylinder head 2 Rear balancer 3 Crankshaft 4 Drain bolt ...
Page 46: ...2 24 LUBRICATION DIAGRAMS SPEC 1 Main axle 2 Drive axle ...
Page 56: ...SPEC ...
Page 57: ...INSP ADJ 3 ...
Page 121: ...INSP ADJ ...
Page 122: ...ENG 4 ...
Page 192: ...ENG ...
Page 193: ...COOL 5 ...
Page 195: ...COOL ...
Page 204: ...CARB 6 ...
Page 206: ...CARB ...
Page 214: ...CARB ...
Page 215: ...CHAS 7 ...
Page 273: ...CHAS ...
Page 274: ...ELEC 8 ...
Page 276: ...ELEC ...
Page 306: ...8 30 LIGHTING SYSTEM ELEC ...
Page 307: ...8 31 SIGNAL SYSTEM ELEC SIGNAL SYSTEM CIRCUIT DIAGRAM ...
Page 322: ...ELEC ...
Page 323: ...TRBL SHTG 9 ...
Page 325: ...TRBL SHTG ...