330
Appendix C: MIDI
02R96 Version 2—Owner’s Manual
13.4.9 Parameter request
(Patch data)
Reception
If [Parameter change RX] is ON and the [Rx CH] matches the Device
Number included in the SUB STATUS, these messages are received. If [Pa-
rameter change ECHO] is ON, these messages are echoed.
When this is received, the value of the specified parameter will be transmit-
ted as a Parameter change.
13.4.10 Parameter change
(Setup memory)
Reception
If [Parameter change RX] is ON and the [Rx CH] matches the Device
Number included in the SUB STATUS, these messages are received. If [Pa-
rameter change ECHO] is ON, these messages are echoed.
When this is received, the specified parameter will be controlled.
13.4.11 Parameter request
(Setup memory)
Reception
If [Parameter change RX] is ON and the [Rx CH] matches the Device
Number included in the SUB STATUS, these messages are received. If [Pa-
rameter change ECHO] is ON, these messages are echoed.
When this is received, the value of the specified parameter will be transmit-
ted as a Parameter change.
13.4.12 Parameter change
(Backup memory)
Reception
If [Parameter change RX] is ON and the [Rx CH] matches the Device
Number included in the SUB STATUS, these messages are received. If [Pa-
rameter change ECHO] is ON, these messages are echoed.
When this is received, the specified parameter will be controlled.
13.4.13 Parameter request
(Backup memory)
Reception
If [Parameter change RX] is ON and the [Rx CH] matches the Device
Number included in the SUB STATUS, these messages are received. If [Pa-
rameter change ECHO] is ON, these messages are echoed.
When this is received, the value of the specified parameter will be transmit-
ted as a Parameter change.
13.4.14 Parameter change
(Function call Library: store / recall)
Reception
If [Parameter change RX] is ON and the [Rx CH] matches the Device
Number included in the SUB STATUS, these messages are received. If [Pa-
rameter change ECHO] is ON, these messages are echoed.
When this is received, the specified memory/library will be stored/recalled.
Transmission
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS
0011nnnn 3n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
MODEL ID (digital mixer)
MODEL ID
00001011 0B
02R96
ADDRESS
00000010 02
Patch data
0eeeeeee ee
Element no. (If ‘ee’ is 0, ‘ee’ is expanded
to two bytes)
0ppppppp pp
Parameter no.
0ccccccc cc
Channel no.
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS
0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
MODEL ID (digital mixer)
MODEL ID
00001011 0B
02R96
ADDRESS
00000011 03
Setup data
0eeeeeee ee
Element no. (If ‘ee’ is 0, ‘ee’ is expanded
to two bytes)
0ppppppp pp
Parameter no.
0ccccccc cc
Channel no.
DATA
0ddddddd dd
data
:
:
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS
0011nnnn 3n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
MODEL ID (digital mixer)
MODEL ID
00001011 0B
02R96
ADDRESS
00000011 03
Setup data
0eeeeeee ee
Element no. (If ‘ee’ is 0, ‘ee’ is expanded
to two bytes)
0ppppppp pp
Parameter no.
0ccccccc cc
Channel no.
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS
0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
MODEL ID (digital mixer)
MODEL ID
00001011 0B
02R96
ADDRESS
00000100 04
Backup data
0eeeeeee ee
Element no. (If ‘ee’ is 0, ‘ee’ is expanded
to two bytes)
0ppppppp pp
Parameter no.
0ccccccc cc
Channel no.
DATA
0ddddddd dd
data
:
:
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS
0011nnnn 3n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
MODEL ID (digital mixer)
MODEL ID
00001011 0B
02R96
ADDRESS
00000100 04
Backup data
0eeeeeee ee
Element no. (If ‘ee’ is 0, ‘ee’ is expanded
to two bytes)
0ppppppp pp
Parameter no.
0ccccccc cc
Channel no.
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS
0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
MODEL ID (digital mixer)
MODEL ID
01111111 7F
Universal
ADDRESS
00010000 10
Function call
00ffffff ff
function
0mmmmmmm mh
number High
0mmmmmmm ml
number Low
DATA
0ccccccc ch
channel High
0ccccccc cl
channel Low
EOX
11110111 F7
End of exclusive
function
number
channel*1)
rx/tx
SCENE RECALL
0x00
0-99, 8192
256
rx/tx*2)
EQ LIB RECALL
0x01
1-200, 8192
0-513
rx/tx
GATE LIB RECALL
0x02
1-128, 8192
0-95
rx/tx
COMP LIB RECALL
0x03
1-128, 8192
0-513
rx/tx
EFF LIB RECALL
0x04
1-128, 8192
0-3
rx/tx
CHANNEL LIB RECALL
0x06
0-128, 8192
0-513
rx/tx
INPATCH LIB RECALL
0x07
0-32, 8192
256
rx/tx
OUTPATCH LIB RECALL
0x08
0-32, 8192
256
rx/tx
Bus to Stereo LIB RECALL
0x09
0-32, 8192
256
rx/tx
Surround Monitor LIB RECALL
0x0A
0-32, 8192
256
rx/tx
AUTOMIX LIB RECALL
0x0B
1-16
256
rx/tx
SCENE STORE
0x20
1-99
256, 16383
rx/tx
EQ LIB STORE
0x21
41-200
0-513, 16383
rx/tx
GATE LIB STORE
0x22
5-128
0-95, 16383
COMP LIB STORE
0x23
37-128
0-513, 16383
rx/tx
EFF LIB STORE
0x24
xx*3)-128
0-3, 16383
rx/tx
CHANNEL LIB STORE
0x26
2-128
0-513, 16383
rx/tx
INPATCH LIB STORE
0x27
1-32
256, 16383
rx/tx
OUTPATCH LIB STORE
0x28
1-32
256, 16383
rx/tx