Digital I/O, Setup, and Utilities
215
02R User’s Guide
02R System Initialization
This operation allows you to reset the 02R to its initial settings. This
operation deletes all scene memories, automix programs, and clears all user
library programs from the channel, dynamics, effect, and EQ libraries.
Initialization consists of:
•
Clearing all user RAM settings: all scene memories (except Scene
Memory 0), automix programs, and user library programs from the
channel, dynamics, effect, and EQ libraries.
•
Initializing the Edit Buffer. See “What is the Edit Buffer?” on page 129
of the User’s Guide.
•
Initializing the Program Change table (list of scene memories to MIDI
Program Change numbers). See “Program Change Assign” on page
160 of the User’s Guide.
•
Coping Scene Memory 0 to the Edit Buffer.
•
Initializing the input and output ports.
•
Calibrating the faders.
•
Refreshing the display.
The SCENE 1/1 page appears.
Fader Calibration
This operation allows you to calibrate the faders.
1.
Turn off the 02R.
2.
Press and hold the [ENTER] button, then turn the 02R back on.
The faders are calibrated.
Note:
If you just want to reset the current mix settings, recall Scene Memory 0.
See “Initial Data and UNDO Memory” on page 129 of the User’s Guide.
Note:
Avoid blocking the fader movements by placing objects on the 02R
while the faders are calibrating themselves. It is possible to damage the faders.
Note:
Avoid blocking the fader movements by placing objects on the 02R while
the faders are being calibrated. It is possible to damage the faders.
1.
Turn off the 02R.
2.
Press and hold the left
CURSOR button.
3.
Turn the 02R back on.
A confirmation dialog
box appears.
4.
Select the EXECUTE icon
by with the CURSOR
buttons and press the
[ENTER] button.
The 02R initializes itself.
When it has completed
the initialization
operation, the SCENE
1/1 page appears.
CURSOR