Page 69
FT-2000D O
PERATING
M
ANUAL
A
DJUSTING
THE
SSB T
RANSMITTED
B
ANDWIDTH
(
SSB M
ODE
)
For transmission on SSB, a default bandwidth of 2.4 kHz is provided. This bandwidth provides reasonable fidelity along
with good talk power, and is typical of the bandwidth used for decades during SSB transmission. However, the bandwidth
may be varied by the operator, so as to provide different levels of fidelity or talk power, according to your preferences.
Here’s how to adjust the transmitted bandwidth on SSB:
1. Press the [
MENU
] button to engage the Menu.
2. Rotate the Main Tuning Dial knob so as to select Menu
item “
085 J3E TX BPF
.”
3. Rotate the [
SUB VFO-B
] knob to select the desired
bandwidth. The available selections are
3000
3000
3000
3000
3000
/
1-30
1-30
1-30
1-30
1-30 (((((50-3000
50-3000
50-3000
50-3000
50-3000)
)
)
)
)
/
1-29
1-29
1-29
1-29
1-29 (((((100-2900
100-2900
100-2900
100-2900
100-2900)
)
)
)
)
/
2-28
2-28
2-28
2-28
2-28 (((((200-
200-
200-
200-
200-
2800
2800
2800
2800
2800)
)
)
)
)
/
3-27
3-27
3-27
3-27
3-27 (((((300-2700
300-2700
300-2700
300-2700
300-2700)
)
)
)
)
/
4-26
4-26
4-26
4-26
4-26 (((((400-2600
400-2600
400-2600
400-2600
400-2600)))))
, and
the default is
3-27
3-27
3-27
3-27
3-27 (((((300-2700
300-2700
300-2700
300-2700
300-2700)))))
Hz. A wider band-
width will provide greater fidelity, while a narrow band-
width will compress the available transmitter power
into less spectrum, resulting in more “talk power” for
DX pile-ups.
4. Press and hold in the [
MENU
] button for two seconds
to save the new setting and exit to normal operation.
A
DVICE
:
The Transmit Monitor is very helpful way of verifying
the effects on fidelity of changing the bandwidth. Press-
ing the [
MONI
] button then adjusting the [
MONI
] knob
for a comfortable listening level while you are trans-
mitting, you will be able to hear the difference in sound
quality as you make changes.
When the optional
DMU-2000
Data Management Unit
is connected, you may verify the effect of your adjust-
ments of the transmitted bandwidth by observing the
Audio Scope on the “Oscilloscope” page.
Q
UICK
P
OINTS
:
The higher fidelity associated with wide bandwidth will
be particularly enjoyable on the low bands, during lo-
cal rag-chew QSOs.
The “3000” setting is a special hi-fidelity setting,
whereby the transmitted bandwidth is in excess of 3
kHz. This selection, in conjunction with judicious ad-
justment of the Parametric Microphone Equalizer (see
next chapter) can provide truly outstanding fidelity and
very natural-sounding audio.
When using the wider bandwidth selections (especially
“3000”), the apparent power output from the transmit-
ter may seem lower. This is because the available power
from the transmitter is being distributed over a wider
bandwidth, and the power detection circuitry does not
compensate for the effect of the bandwidth selection
(it is calibrated in the default 2.4 kHz bandwidth).
Main Tuning Dial Knob
[SUB VFO-B] Knob
[MENU] Button
E
NHANCING
T
RANSMIT
S
IGNAL
Q
UALITY
Summary of Contents for FT-2000D
Page 7: ...Page 5 FT 2000D OPERATING MANUAL NOTE ...
Page 43: ...Page 41 FT 2000D OPERATING MANUAL NOTES ...
Page 75: ...Page 73 FT 2000D OPERATING MANUAL ENHANCING TRANSMIT SIGNAL QUALITY NOTE ...
Page 133: ...Page 131 FT 2000D OPERATING MANUAL MENU MODE NOTE ...
Page 137: ...Page 135 FT 2000D OPERATING MANUAL NOTE ...