Revision 1.1
WebSwitch™ Users Manual
Email Option (Model XRDI-WS3P only)
Simple email messages can be sent when outlets are turned on or off. This parameter is used to
specify what conditions, if any, will cause email messages to be sent. Note that email notification will
work only if the email settings are correctly set up in the Network setup page. The following options
are available:
-
No Email Messages
:
No email notifications will be sent when outlet changes.
-
Send Email when outlet on
:
Email notifications will be sent when outlet state changes to
on
.
-
Send Email when outlet off
:
Email notifications will be sent when outlet state changes to
off
.
-
Send Email when outlet changes state
:
Email notifications will be sent when outlet changes
state to
on
or
off
.
-
Send Email on pulse/reboot:
Email notifications will be sent when the outlet is pulsed or
automatically rebooted.
Note: The default setting for this field is
No Email Messages.
Use Email Address (Model XRDI-WS3P only)
If email messages are to be sent out when outlets change state, these check boxes specify to which
email addresses the message will be sent. Email addresses specified on the Network setup tab will
be displayed next to each check box. By default, no boxes are checked.
Remote Service/SNMP
When this box (Send State Msg/Trap on Input Change) is checked, SNMP traps and/or State
messages will be sent whenever the outlet state changes.
The following parameters are available only in
Normal
mode
Outlet State at Powerup
This drop down menu lets the user specify the state of each of the internal relays when the
WebSwitch™ is powered up. The following options can be selected:
-
on (unless overridden by event)
:
the outlet will be on when power is applied to WebSwitch™.
-
off (unless overridden by event)
:
the outlet will not be off upon power up. This is the default
setting.
-
last state (unless overridden by event)
(Model XRDI-WS3P)
: upon power up, the outlet will
return to its last state when WebSwitch Plus™ was powered off.
Note: These settings affect the Pulse/Reboot command as follows:
Outlet State at Powerup Pulse/Reboot Command effect
On
Outlet will Pulse Off when a pulse command is received.
Off
Outlet will Pulse On when a pulse command is received.
Last State
Outlet will Pulse On when a pulse command is received.
Note: Each setting will be overridden by an active event.
Xytronix Research & Design, Inc.