Revision 1.1
WebSwitch™ Users Manual
Section 2: Installation and Setup
Installation consists of mounting WebSwitch™, connecting to an IP Network, providing power, and
configuring via a web browser.
For WebSwitch Plus™ models, inputs and sensors can be wired to the device using the 5-position
terminal connector.
2.1 Mounting
WebSwitch™ can be placed upon a table top, wall mounted, or rack mounted (with optional rack mount
kit). It should be mounted in a clean, dry location where it is protected from the elements. Ventilation is
recommend for installations where ambient air temperature is expected to be high.
To mount WebSwitch™ to a wall, use two #8 screws. Attach the screws to the wall horizontally spaced
6 3/8 inches (162 mm) apart. The head of the screws should be about 1/10 inch away from the wall. See
Appendix I
for additional mechanical details.
If WebSwitch™ is to be rack mounted, the rack mounting kit should be purchased separately. Insert the
rack mount ears on both sides of WebSwitch™. Secure the rack mount ears by inserting the two pins on
the bottom of the unit. Place WebSwitch™ in the desired location on the rack. Use four rack mount
screws to secure WebSwitch™ to the rack.
Xytronix Research & Design, Inc.
12
Figure 2.1a - WebSwitch™ Shown with Optional Rack Mount Ears