Appendix B: Installing New Firmware
WebRelay-10 Users Manual
downloaded from the ControlByWeb™ web site.
Device Upgrade Procedure
Carefully follow the following steps to put the WebRelay-10 into bootloader mode and perform the
upgrade:
1.
Remove DC power to WebRelay-10.
2.
Using a small, non-conductive tool, press and hold the reset button..
3.
While holding the reset button, apply power to WebRelay-10. The Link and Act lights will flash. Continue
to hold the reset button for the next step.
4.
While holding the reset button, press the Upload Firmware button at the bottom of the ControlByWeb™
Programmer window. After the programming process begins, the reset button can be released
5.
Programming will take approximately 20-30 seconds, the Link LED will stop flashing and remain lit.
WebRelay-10 will be set to factory defaults with an IP address of 192.168.1.2.
6.
Refer to section
2.3 Establishing Communication for Setup
to reconfigure the WebRelay-10. Verify the
new version of firmware has been installed by viewing the default setup page with a web browser
(
).