5015T Flat Panel Industrial Monitor Chapter 2 Installation
15
142029 (D)
2. If present, keep enclosure doors or openings closed at all times, to avoid the
accumulation of foreign matter inside the workstation.
3. Never subject the unit to any installation or service procedures unless power is
removed and the area is known to be non-hazardous. This includes the installation or
removal of power cables, communication cables, or removal of the rear cover of the
unit.
Only technically qualified service personnel should perform all installation and service.
These workstations are designed to require no service in the course of normal operation
by an operator.
Safety Agency Approval
The Xycom Automation systems are designed to meet the following standards:
•
Underwriters Laboratories Inc., UL 1604 Standard for Safety
Electrical equipment for use in Class I and Class II, Division 2, locations
•
Underwriters Laboratories Inc., UL 60950, Information Technology Equipment
•
Canadian Standard Association, Specification C22.2 No. 213-M1987
Non-incendiary electrical equipment for use in Class I, Division 2 hazardous
locations
•
Canadian Standards Association, Specification C22.2 No. 950
Information Technology Equipment
•
EN 60950, Information Technology Equipment