5015T Flat Panel Industrial Monitor                                                                                                 Chapter 2 Installation 

15 

142029 (D)

 

2.  If present, keep enclosure doors or openings closed at all times, to avoid the 

accumulation of foreign matter inside the workstation. 

 
3.  Never subject the unit to any installation or service procedures unless power is 

removed and the area is known to be non-hazardous. This includes the installation or 

removal of power cables, communication cables, or removal of the rear cover of the 

unit. 

Only technically qualified service personnel should perform all installation and service. 

These workstations are designed to require no service in the course of normal operation 

by an operator. 

Safety Agency Approval 

The Xycom Automation systems are designed to meet the following standards: 

• 

Underwriters Laboratories Inc., UL 1604 Standard for Safety 

Electrical equipment for use in Class I and Class II, Division 2, locations 

• 

Underwriters Laboratories Inc., UL 60950, Information Technology Equipment 

• 

Canadian Standard Association, Specification C22.2 No. 213-M1987 

Non-incendiary electrical equipment for use in Class I, Division 2 hazardous 

locations 

• 

Canadian Standards Association, Specification C22.2 No. 950 

Information Technology Equipment 

• 

EN 60950, Information Technology Equipment 

 

Summary of Contents for 5015T

Page 1: ...5015T 15 FLAT PANEL INDUSTRIAL MONITOR FLAT PANEL INDUSTRIA Hardware Guide...

Page 2: ...io communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense For E...

Page 3: ...initions 12 Power Switch 13 Cable Connections 14 Operation and Maintenance 14 Safety Agency Approval 15 Chapter 3 Monitor Settings 16 Mode and Image Adjustment 16 On Screen Display Select Switch 16 An...

Page 4: ...panel display with XGA 1024x768 resolution Large viewing area 12 13 x 9 14 in 308 2 x 232 1mm dot pitch 0 012 x 0 012in 0 287 x 0 287 mm Operator input through integrated high performance touchscreen...

Page 5: ...5T 24VDC units Manual Overview The manual is divided in the following chapters Chapter 1 Product Overview Chapter 2 Installation Chapter 3 Monitor Settings Chapter 4 Operator Input Chapter 5 Hardware...

Page 6: ...5015T Flat Panel Industrial Monitor Chapter 1 Product Overview 3 142029 D Product Dimensions...

Page 7: ...d These buttons are used to adjust backlight brightness C Front Key Switch POWER LED 4 Indicates whether the monitor is on or off The LED is lit green when in use D Power input terminal block Used to...

Page 8: ...n 0 015 peak to peak displacement 2 5 g maximum acceleration Altitude Sea level to 10 000 ft 3 000 m Sea level to 40 000 ft 12 000 m Electrical AC power 100 240 VAC 0 8 0 4A 50 60 Hz DC power 18 32 VD...

Page 9: ...ovide data such as the size and types of conductors color codes and connections necessary for safe grounding of electrical components The code specifies that a grounding path must be permanent no sold...

Page 10: ...ture is higher than the specified maximum in the enclosure use a fan or air conditioner to lower the temperature Electrical Noise Electrical noise is seldom responsible for damaging components unless...

Page 11: ...sure You can maintain the NEMA 4 seal by mounting the unit in an approved enclosure that has a 14 gauge 0 075 in 1 9 mm thick steel or 0 125 in 3 2 mm thick aluminum front face Place the unit at a com...

Page 12: ...in one of the walls of your NEMA enclosure Enclosures made of heavier gauge metal work better in that they won t deform or bend as easily when the monitor s sealing gasket is compressed Next hold the...

Page 13: ...tor Chapter 2 Installation 10 142029 D The following figures show the twelve 12 insertion slot locations of the 5015T installation fasteners Insert the hook section into the slot and tighten the faste...

Page 14: ...y when adding additional cards that they met operating conditions for Class I Division 2 hazardous locations It is the responsibility of the customer to ensure that the product is properly rated for t...

Page 15: ...not familiar with generic hazardous locations requirements Persons responsible for the installation of this equipment in Hazardous Locations are responsible for ensuring that all relevant codes and r...

Page 16: ...in suspension in the air as a result of the following infrequent malfunctioning of handling or processing equipment combustible dust accumulations on or in the vicinity of electrical equipment may be...

Page 17: ...should be a metal conductive type e g molded zinc and the ground shield braid should be well terminated directly to the connector housing Do not use a shield drain wire The outer diameter of the cabl...

Page 18: ...all installation and service These workstations are designed to require no service in the course of normal operation by an operator Safety Agency Approval The Xycom Automation systems are designed to...

Page 19: ...the left hand side of the unit towards the front Some or all of a front key switch is locked by the position of the OSD Select switch Incorrect starting of the OSD can be prevented Caution Please use...

Page 20: ...turned off while displaying the Adjustment Menu Adjusting the Backlight The backlight brightness can be adjusted while the On Screen Display OSD Menu is not being displayed When the OSD Menu is being...

Page 21: ...Xycom Automation CD Opening the Adjustment Pattern for Windows only The software for the adjustment pattern can be downloaded from the Xycom Automation CD To install the adjustment pattern follow the...

Page 22: ...to adjust clock phase h pos and v pos Gain Control Opens the Gain Control menu allows you to adjust black level and contrast White Balance Opens the White Balance menu allows you to adjust color tone...

Page 23: ...t signal even if menu options can be selected the display may not change Menu Option Description OSD H Position The horizontal position of the OSD display can be adjusted using the buttons OSD V Posit...

Page 24: ...andard of color representation specified by IEC International Electrotechnical Commission Color conversion is made after taking account of liquid crystal s characteristics and represents color tone cl...

Page 25: ...estart the 4 point calibration will automatically run It is recommended that you keep all default settings when installing the driver Calibrating the Touchscreen If you need to recalibrate the touchsc...

Page 26: ...al 10 11 12 Hsync 13 Vsync 14 15 Serial Interface Function RS 232C Data Transmission Speed 9600 bps Data Length 8 bits Stop Bit 1 bit Parity None Serial Signal Input Connector Pin Number Signal Name F...

Page 27: ...use parts equivalent to those listed below Description Quantity Vendor Part No 9 pin female connector 2 AMP 205203 3 9 pin hood 2 AMP 745171 2 Cable 1 up to 50 Belden 9925 3 conductor Sockets 12 AMP...

Page 28: ...sting from the Microsoft Diagnostic utility MSD or other diagnostic applications 5 Details of attempts made to rectify the problem s and results 6 The log number assigned from Xycom Automation Technic...

Page 29: ...142029 C Xycom Automation Inc 750 North Maple Drive Saline MI 48176 734 429 4971 Fax 734 429 1010 http www xycom com...

Reviews: