Product Specifications and Ratings
Environmental
Operating Non-operating
Thermal
0°C to 50°C (32°F to 122°F)
-20°C to 60°C (-4°F to 140F)
Humidity
20% to 80% RH, non-condensing 20% to 80% RH, non-condensing
Shock
15 g peak acceleration,
11 msec duration
30 g peak acceleration,
11 msec duration
Vibration,
5-2000 Hz
0.006" peak-to-peak
displacement
1.0 g maximum acceleration
0.015" peak-to-peak displacement
2.5 g maximum acceleration
Altitude
Sea level to 10,000 ft. (3,000 m)
Sea level to 40,000 ft. (12,000 m)
Electrical
AC power: 100-240 VAC, 0.8 – 0.4A, 50/60 Hz
DC power: 18 - 32 VDC, 1 A maximum
Front Panel/Enclosure
NEMA 4/4X/12
Regulatory Compliance
CE
EN 55022: Class A
EN 61000-6-2
EN 60950
EN 61000-3-2
EN 61000-3-3
FCC
47 CFR, Part 15, Class A
Safety Agency Approvals
UL
UL 60950
UL 1604*
CUL
CSA-C22.2, #950
CSA-C22.2, #213*
* Suitable for use in Class I, Division 2, Groups A, B, C and D and Class II, Division 2, Groups F
and G Hazardous Locations or Non-Hazardous Locations only.
Temperature Codes: T4 (5015T), T4A (5015T-24V)