15
6.0.2.2 Hardware Status Register
Figure 4 shows the Temperature Status Register. It also takes the standard SCPI structure.
The Hardware Status Register four individual condition inputs are:
6.0.2.2.112V Bias Error. The internal 12V bias is either too low or too high for valid operation.
6.0.2.2.23.3V Bias Error. The internal 3.3V bias is either too low or too high for valid operation.
6.0.2.2.3PFC Failure Pending. The unit’s PFC supply has either failed or primary power has been removed.
6.0.2.2.4PFC Failure. The unit’s PFC supply has failed.
6.0.2.2.5SCPI Access
Access to the Temperature Status Register is via the following commands:
STATus:QUEStionable:HARDware[:EVENt]?
Rtn Event register
STATus:QUEStionable:HARDware:CONDition?
Rtn Condition register
STATus:QUEStionable:HARDware:ENABle <value>
Set Enable register
STATus:QUEStionable:HARDware:ENABle?
Rtn Enable register
Figure 4. Temperature Status Register