14
6.0.2
Questionable Status Fan-Out Registers
In addition, there are two fan-out structures feeding the Temperature Error and Hardware Error inputs.
6.0.2.1 Temperature Status Register
Figure 3 shows the Temperature Status Register. It also takes the standard SCPI structure.
The Temperature Status Register two individual condition inputs are:
6.0.2.1.1
Output Board Over-Temperature. The output board temperature surpasses its allowed operating limit.
6.0.2.1.2
Primary Board Over-Temperature. The primary board temperature surpasses its allowed operating limit.
6.0.2.1.3
Fan Stall. The cooling fan is non-operative.
6.0.2.1.4SCPI Access
Access to the Temperature Status Register is via the following commands:
STATus:QUEStionable:TEMPerature[:EVENt]?
Rtn Event register
STATus:QUEStionable:TEMPerature:CONDition?
Rtn Condition register
STATus:QUEStionable:TEMPerature:ENABle <value> Set Enable register
STATus:QUEStionable:TEMPerature:ENABle?
Rtn Enable register
Figure 3. Temperature Status Register