OVEN SERVICE PROCEDURES
Optical Flame Sensor
Shutter
New Installation– The shutter has been set at the factory. This should not need adjust-
ed. If found loose call technical support for settings.
High Altitude– 6,000 ft and above the shutter may need adjusted. This should only be
adjusted to keep flame lit and combustion to a minimum.
NOTE
Air Shutter Settings - Original
Natural Gas
LP Gas
Standard
3.0
3.0
HP
9.0
9.0
All Oven Models
Shutter
Recommended Burner Shutter Settings