12 Cleaning and Maintenance – Scan System
Wide Format Copy System User Guide
147
Cleaning the Calibration Strip
Perform the following steps monthly:
1. Press
the
Menu
key, then scroll to the Diagnostic and press the
Enter
key.
•
Scroll to CLEAN CAL ZONE and press the
Enter
key.
•
Press
the
Enter
key to select CLEANING POSITION.
NOTE: The Top Cover must be closed while running this test.
2. Raise the Top Cover.
3. Inspect the Calibration Strip.
4. Place a small amount of platen glass cleaning fluid (Xerox 43P81) on a clean, lint-
free towel (600S4372) and clean the Calibration Strip.
5. Lower the Top Cover.
6. Press
the
Enter
key to select HOME POSITION.
7. Press
the
Exit
key to exit the CLEAN CAL ZONE.
8. Press
the
Menu
key to return to the READY screen. The Calibration Strip
automatically returns to its home position.