Technical Specification
Chilli Dimmer 73-853-00 Issue 8
Page 30 of 30
Technical Specification
Electrical
Supply Voltage:
230V +10% / -15%
Supply Frequency:
45 to 65Hz
Maximum Supply Current:
0410i:
40A Single phase
0410HF:
40A Single phase
1210i:
40A 3 phase star
1210HF:
40A 3 phase star
1216i:
64A 3 phase star
2410i:
80A 3 phase star
2416i:
128A 3 phase star
625i:
50A 3 phase star
Maximum Load per Channel
0410i:
10A Max
0410HF:
10A Max
1210i:
10A Max
1210HF:
10A Max
1216i:
16A Max
2410i:
10A Max
2416i:
16A Max
625i:
25A Max
DMX Input:
USITT DMX512/1990
Ground referenced receiver
Internal switchable termination
RDM Support:
Protocol Version:
1.0
Device Model ID:
The first 5 digits of the stock
number are used for this, e.g.
01105 (0x0451) for the Chilli
Pro 1210i.
Supported Parameters:
DMX_START_ADDRESS,
SENSOR_DEFINITION,
SENSOR_VALUE,
DEVICE_LABEL,
MANUFACTURER_LABEL,
DEVICE_MODEL_DESCRIPTION
Sub Devices:
One per channel.
Mechanical
Size:
0410i:
400 x 220 x 155 mm
0410HF:
400 x 220 x 155 mm
1210i:
850 x 325 x 155 mm
1210HF:
550 x 220 x 155 mm
1216i:
850 x 325 x 155 mm
2410i:
1000 x 632 x 155 mm
2416i:
1000 x 632 x 155 mm
625i:
850 x 325 x 155 mm
Maximum Weight:
0410i:
7.0 Kg
0410HF:
4.0 Kg
1210i:
18.0 Kg
1210HF:
9.0 Kg
1216i:
24.0 Kg
2410i:
47.0 Kg
2416i:
50.0 Kg
625i:
26.5 Kg
Environmental
Operating Temperature Range:
+5°C to +40°C
Relative Humidity:
5% to 95% Non-condensing
EMC
Emissions:
EN55015 : 2000
+A1 : 2001
+A2 : 2002
Immunity:
EN61000-6-1 : 2001
EN61000-6-3 : 2001
Electrical Safety:
EN60950-1 : 2002
Cooper Controls Ltd.
Usk House
Llantarnam Park
Cwmbran
Gwent NP44 3HD
United Kingdom
Tel: +44 (0)1633 838088 *
Fax: +44 (0)1633 867880
e-mail: [email protected]