Installation
Chilli Dimmer 73-853-00 Issue 8
Page 7 of 30
Load Connections
4 Channel Unit
The load cables are connected to
the terminal strips located on the
left hand side of the unit. The
outputs will accept a maximum
6mm
2
cable.
Do not use a common neutral for
multiple loads.
4 Channel HF Unit
The
switched
outputs
are
connected to the terminal strips
located on the left hand side of the
unit. The outputs will accept a
maximum 6mm
2
cable.
Do not use a common neutral for
multiple loads.
The HF controller outputs are
connected to the terminal strip
located on the right hand side of
the unit and will accept a maximum
2.5mm
2
cable.
NOTE - The HF controller
outputs in this product are
electrically isolated from mains
earth and mains phase.
They are only intended for
connection to electronic ballasts
for fluorescent fittings.
They are not intended to control,
and should not be connected at
any time, to any earth referenced
electronics.