Installation
Chilli Dimmer 73-853-00 Issue 8
Page 16 of 30
Network Connection
All network and control cables
should enter the dimmer through
the segregated route at the bottom
of the dimmer.
Segregation between control data
cabling and power wiring should be
maintained for reasons of safety
and noise immunity.
Control data cabling should be run
in separate or divided metal
trunking or conduits.
Where cables are run outside
trunking or conduits there should
be 300mm separation between
them and where they cross they
should do so at right angles.
Inside the dimmer, the terminals
for network connections use two
part connectors.
Pull the connector from the PCB,
connect the wires from the CAT 5
cable and push the connector back
onto the PCB, ensuring correct
orientation (see figure 2-15).
Figure 2 - 15: Network Connections