26
XCell
TM
ATF System with C410:V3 Controller
User Guide
The main screen displays the parameters in the following tables:
Field
Description
Date/Time
Displays current Date and Time
User ID
Displays current User ID
Entries in Main
Screen
Field entries by Administrator (or, if authorized, by Engineer) through the
Main screen:
P-Flow
E-Flow
PRV1
PRV2
PV1
PV2
P-FLOW SP
Displays current P-Flow Set Point (SP) (LPM)
P-FLOW PV
When running, displays pump Flow rate Process Value (PV) of last pump
cycle (LPM)
P-FLOW
Calculated
Displays current P-Flow Calculated cycle time (Sec)
P-FLOW Actual
When running, displays Actual pump flow cycle Time of last pump cycle
(Sec)
E- FLOW SP
Displays current E-Flow Set Point (SP) (LPM or Seconds)
E- FLOW PV
When running, displays pump exhaust Flow rate Process Value (PV) of last
pump cycle (LPM)
E-FLOW
Calculated
Displays current E-Flow Calculated cycle time (Sec)
E-FLOW Actual
When running, displays Actual pump exhaust cycle Time of last pump cycle
(Sec)
PV1
Displays current position Set Point of Flow Proportional Valve (0-100%)
PV2
Displays current position Set Point of Exhaust Proportional Valve (0-100%)
PRV1
Displays current setting of automatic pressure regulator (0 to 35psi)
PRV2
Displays current setting of automatic exhaust regulator (-15 to 0 psi)
P2
Displays current pressure between controller and Diaphragm Pump (PSI)
Controller
Status
Displays current controller status:
PUMP OFF
PUMP ON
PUMP WARNING
PUMP ALARM
SYSTEM STOP PRESSED