Power System Monitoring on the Internet
975-0330-01-01
3–23
To configure the Gateway, router and Widget for power system
monitoring on the Internet:
1. View the Gateway configuration web page.
2. On the Gateway configuration web page, click
Network
Configuration
.
3. Clear the
Get Address Dynamically
check box.
4. Change the last field in the IP address to a number that is outside the
DHCP server IP Address Range. You can find this address range on
your router’s configuration page. Do not use 0, 255, or the same
number your router uses (usually 1).
5. On the Gateway configuration web page, click
Save and
Apply
.
6. In the address bar of the web browser displaying the configuration
web page, overwrite the last part of the IP address with the number
you entered in step 4.
Change number
in this field
Note:
After restarting the Widget on your local network, you may need to
manually set the Device IP Address in Widget Preferences to match the
chosen address if the Widget cannot automatically detect the new address.