Installation
2–10
975-0330-01-01
Connecting the Gateway to a XW Hybrid Inverter/Charger
The XW Hybrid Inverter/Charger is equipped with two Xanbus network
ports (see Figure 2-5). These ports may not be immediately accessible if a
conduit box is installed on the bottom of the inverter/charger. Follow the
guidelines for connecting devices and terminating the network as
described in “Network Layout” on page 2–8, and in “Xanbus Network
Installation” in the
XW Power System Installation Guide
.
Figure 2-4
GT Inverter Xanbus (RJ-45) Ports
Xanbus (RJ-45) ports
Terminator
Figure 2-5
XW Inverter/Charger Xanbus Ports
CHASSIS
GROUND
AC SYNC
XANBUS
BTS
AUX
POS
NEG
REFER TO MANUAL
270-1407-01-01
TIGHTENING TORQUE
#6 - #4: 45 in-lbs
#2 - 1/0: 50 in-lbs
TIGHTEN TO
15-16 ft-lbs
270-1408-01-01
Xanbus ports