975-0390-01-01
55
NOTE
: These specifications refer to inverter mode.
DC Input
1000 - watt Models
1500 | 1800 -watt
Models
Operating voltage range for all
models including some Freedom
HF 1800 T (806-1840-01)
10.5–15.5 VDC (low
limit)
11.8–15.5 VDC
(high limit)
10.5–15.5 VDC (low
limit)
11.8–15.5 VDC
(high limit)
Operating voltage range for
Freedom HF 1500 and Freedom
HF 1800 T (806-1840-01, 806-
1840-03, 806-1840-04, 806-
1840-05)
n/a
10.5–15.5 VDC (low
limit)
11.8–15.5 VDC
(mid limit)
12.1–15.5 VDC
(high limit)
Safe non-operating voltage range
0–16 VDC
0–16 VDC
Nominal voltage for all models
12.5 VDC
12.5 VDC
Nominal current at full load
100 ADC
180 ADC
AC Output
1000 -
watt Models
1500 | 1800 -watt
Models
Output voltage
115 VAC
115 VAC
Continuous power
1.0kW @ 25 °C
1.8kW @ 25 °C 1.5kW
@ 25 °C (Freedom
HF 1500 only)
Surge power
17 AAC (2kW for
200 ms)
30 AAC (3.6kW for
300 ms)
Max short-circuit current
55 AAC peak
55 AAC peak
Frequency
60 Hz
60 Hz
AC Output
1000 -
watt Models
1500 | 1800 -watt
Models
Wave shape
Modified Sine
Wave
Modified Sine Wave
Power derating above 40 °C
ambient temp
See
Invert Power Derating vs. Ambient
Peak efficiency
≥ 87%
≥ 87%
Full load efficiency
≥ 80%
≥ 80%
Other
1000 -
watt Models
1500 | 1800 -watt
Models
No load input power (producing
output voltage)
≤
10W
≤
10W
Off mode current draw
≤
1mA
≤
1mA