Troubleshooting Reference
50
Freedom HF Owner's Guide
Problem
Possible Cause
Solution
Battery charging current is lower than the
charging set point during bulk charge mode.
Ambient (environment) temperature is
high.
Do not be alarmed, the unit is performing normally. The charging
current automatically de-rates at high ambient temperature.
Improve ventilation. Make sure the unit’s ventilation openings are
not blocked.
Alarm does not sound when an error is
encountered.
Alarm is turned OFF.
Press and hold the Select button for two seconds to disable (or
enable) the audible alarm. See
Turning the Audible Alarm ON or
.
Low output voltage
(96 volts AC–104 volts AC) during Inverter
mode.
You are using a voltmeter that cannot
accurately read the RMS voltage of a
modified sine wave.
Use a true RMS reading voltmeter such as the Fluke 87.
Table 7 Troubleshooting reference