Configuration
28
Freedom HF Owner's Guide
5. Press and hold the Select button for five seconds to make
the setting permanent.
To adjust the alarm setting:
By default the alarm is set to ON.
ON (“
AL1
”) will sound the alarm on all warning and fault conditions.
OFF (“
AL0
”) will mute the alarm.
1. Press and hold the Inverter Power button for five seconds.
2. Press the Inverter Power button twice. The LED screen will
flash “
AL
” intermittently.
3. Press the Select button once. The LED screen will display
the present (or most recent) alarm setting.
Example, “
AL1
” for an inverter mode setting of ON.
4. Continue pressing the Select button to cycle through the
two settings – “
AL0
” and “
AL1
” until you reach the desired
setting.
5. Press and hold the Select button for five seconds to make
the setting permanent.
To adjust the low battery shutdown setting:
By default the low voltage setting is set to Low (“
sdL
”).
Low (“
sdL
”) sets the low battery shutdown threshold to 10.5 V for
all models except Freedom HF 1500.
Middle (“
sdn
”) is only available to Freedom HF 1500 and some
models of Freedom HF 1800 T. It sets the low battery shutdown
threshold to 12.1 V and 11.8 V respectively.
High (“
SdH
”) sets the low battery shutdown threshold to 11.8 V for
all models except Freedom HF 1800 T which sets the low battery
shutdown threshold to 12.1 V.
See
Selectable Low Battery Shutdown on page 15
for a summary.
1. Press and hold the Inverter Power button for five seconds.
2. Press the Inverter Power button three times.
The LED screen will flash “Sd” intermittently.
3. Press the Select button once.
The LED screen will display the present (or most recent)
low voltage setting. Example,
“
SdL
” for a low shutdown
voltage setting.
4. Continue pressing the Select button to cycle through the
two – “
SdL
” and “
SdH
” settings (or through three settings
a
)
until you reach the desired setting.
5. Press and hold the Select button for five seconds to make
the setting permanent.
a. In addition to two settings “
SdL
” and “
SdH
”, the middle setting “
Sdn
” is available only for Freedom HF 1500 and
1800 T models (PNs: 806-1544, 806-1840-01, 806-1840-03, 806-1840-04, 806-1840-05, but not some 806-1840-
01 which has only “
SdL
” and “
SdH
”).