Configuration
975-0390-01-01
27
Input Circuit Breaker
or fuse size (Amps)
Charger DC
Current Setting
(Amps)
Maximum By-pass AC
Current Available
(Amps)
All other
models
Freedom
HF 1055
15
2
5
12.5
5
12.5
10
15
9.5
20
35
4.0
40
55
0
20
2
5
17.5
5
a
17.5
10
15
14.5
20
35
9.0
40
b
55
5.0
30
2
5
27.5
5
a
27.5
10
15
24.5
20
35
19.0
40
b
55
15.0
a. Available only for the Freedom HF 1000 and 1055 models.
b. Available only for Freedom HF 1500/1800 models.
To change the inverter mode setting:
By default the inverter mode is set to ON (“
In1
”).ON (“
In1
”) will
put the inverter on standby. This means when shore power is
present, AC shore power will pass through as AC output. And
when shore power is not available, the inverter function will take
power from the battery and provide AC output power. When the
inverter mode is ON, you can manually turn the inverter function
ON or OFF by using the Inverter Power button. See “Operating in
Inverter Mode” on page 17.
OFF (“
In0
”) will completely disable inverter function. This means
when shore power is present, AC shore power will still pass
through as AC output. However, when shore power is not
available, the inverter function remains disabled and therefore no
AC output power. When the inverter mode is OFF, you cannot
manually turn the inverter function ON or OFF by using the
Inverter Power button.
1. Press and hold the Inverter Power button for five seconds.
2. Press the Inverter Power button once. The LED screen will
flash “
In
” intermittently.
3. Press the Select button once. The LED screen will display
the present (or most recent) inverter mode setting.
Example, “
In1
” for an inverter mode setting of ON or “In0”
for an inverter mode setting of OFF.
4. Continue pressing the Select button to cycle through the
two settings – “
In1
” and “
In0
” until you reach the desired
setting.