Display Panel
975-0390-01-01
21
Display Panel
FREEDOM HF
Input Voltage(V)
Select
STATUS
Battery
Fault
Utility
Input Current (A)
Output Power (kW)
1
3
2
4
Figure 9 Display Panel (All Models)
Item
Description
1
Inverter Power button
is the main unit switch that turns the
Freedom HF’s inverter function ON or OFF.
2
Three-digit LED display screen
shows status information and
fault codes.
3
Status LED
indicates the mode of operation with a three-color LED.
4
Select button
changes status information displayed on the display
screen.
IMPORTANT
: See
Display Panel Operation on page 29
for detailed information on operating the panel’s
buttons
Remote and Power Module Panel
1
2
a b c
Figure 10 Remote and Power Module Panel (Freedom HF 1055
EMS,1800 EMS)
Item
Description
1
Remote jack is used for connecting the Display panel that ships with
the Freedom HF 1055 EMS and 1800 EMS. Each shipment comes
with a 25-foot communications cable as well.
2
Power module has one fuse and three contacts for wires that
connect to:
a. an auxiliary 12-volt DC OUT terminal,
b. an Ignition Control terminal, and
c. a Disable terminal.
NOTE
: The Ignition Control and Disable terminals are connected by a jumper wire that acts to
disable ignition control. Removing the jumper wire will enable ignition control.
For instructions on how to enable or disable Ignition Control, see
the Installation Guide.