Configuration
26
Freedom HF Owner's Guide
Adjusting Feature Settings
The Power and Select buttons can be used to:
n
change the charging current setting
n
change the inverter mode setting
n
disable or enable the audible alarm
n
change the shutdown setting
n
return to factory default settings
Figure 14 Display Panel
FREEDOM HF
Input Voltage(V)
Select
STATUS
Battery
Fault
Utility
Input Current (A)
Output Power (kW)
To cycle through the various feature settings:
1. Press and hold the Inverter Power button for five seconds to
enter the feature settings mode.
2. Press the Inverter Power button to toggle between the
following information.
Setting
LED Screen
Charging Current Setting
Cur
Inverter Mode Setting
IN0
Alarm Setting
aL
Shutdown Setting
sd
Factory Setting
def
To change the charger’s charging current setting:
By default the charging current is set to 20A for Freedom HF 1000,
55A for Freedom HF 1055, and 40A for Freedom HF 1500/1800
models.
1. Press and hold the Inverter Power button for five seconds.
The LED screen will flash “
Cur
” intermittently.
2. Press the Select button once.
The LED screen will display the present charging current
setting.
Example, “
40A
” for a 40 A setting.
3. Press the Select button again to change to the next setting.
The LED screen shows the next setting. Example, “
2A
” for a
2 A setting.
4. Continue pressing the Select button to cycle through each
of the available settings – “
2A
”, “
10A
”, “
20A
”, and “
40A
”, such
as in the case of Freedom HF 1800, until you reach the
desired setting.
5. Press and hold the Select button for five seconds to make
the setting permanent.