Introduction
Over temperature Alarm and Shutdown
During inverter mode,
the Freedom HFS automatically alerts you if it is overheating and
approaching the over-temperature shutdown limit.
The Freedom HFS automatically shuts down when the limit is
exceeded.
Low Power Consumption
When the Freedom HFS is inverting
without a load, it draws less than 0.6 amp of current from the battery
(or battery bank).
This feature allows the unit to operate without draining too much
stored energy.
Battery-friendly Charging
For the inverter to perform
effectively, the batteries must be charged correctly. The Freedom
HFS has a built-in three-stage charging system that extends the life
and optimizes the performance of the batteries.
In addition to the numerous features which let you maximize your
battery’s life and performance, the Freedom HFS—unlike many
chargers—also has the ability to recharge a near-zero
a
voltage
battery and an ignition-switched 20-amp auxiliary 12-volt power
source
b
.
Selectable Low Battery Shutdown
The low battery shutdown
for the inverter can be manually selected by the user by choosing a
low (10.5 V), middle (11.8 V), or high (12.1 V) setting.
Ignition Control
The Freedom HFS provide two user-selectable
ignition control method:
•
Ignition Lockout
: The Freedom HFS features the ability
to inhibit the inverter from operating in the absence of a
voltage signal from a vehicle's ignition circuit. This is
particularly useful if the inverter is required to operate only
when a vehicle's engine is running.
•
Ignition Auto-on
: The Freedom HFS can automatically
turn the inverter on and off with the vehicle's ignition
circuit.
Inverter Power Save
The Freedom HFS has the ability to
automatically turn off after 25 hours of continued operation of loads
that are under 50 watts. It is designed to, in conjunction with LBCO,
to prevent the battery from deep discharge.
a.Near-zero or dead batteries can be recharged. However, some batteries which have
been left uncharged for days can become severely damaged thus, recharging is futile.
b.Available on the Freedom HFS 1055 120VAC EMS model (PN: 807-1055-02) and
Freedom HFS 2055 120VAC EMS model (PN: 807-2055-02). The inverter/charger
features a 20-amp fused and switched output voltage supplied from the inverter/char-
ger's positive terminal. When connected to a vehicle's ignition signal, a switched pos-
itive voltage is available to power auxiliary circuits that are required to operate only
when the vehicle is operational.
Freedom HFS IC Owners Guide.book Page 3 Friday, September 11, 2015 2:54 PM
Summary of Contents for 807-1055
Page 2: ...Freedom HFS IC Owners Guide book Page ii Friday September 11 2015 2 54 PM ...
Page 12: ...Freedom HFS IC Owners Guide book Page x Friday September 11 2015 2 54 PM ...
Page 14: ...Freedom HFS IC Owners Guide book Page ii Friday September 11 2015 2 54 PM ...