No output voltage. The status LED is red.
AC shore power is not available or out of operating range and the inverter has shut down with the display
screen showing one of the following error codes:
•
Low input voltage (fault code
)
•
Check the DC connections and the cable.
•
Recharge the battery.
•
High input voltage (fault code
) •
Verify the unit is connected to a 12V battery.
•
Check the voltage regulation of the external charging system
(if any).
•
Unit overload or AC output short
circuit (fault code
)
•
Reduce the load. Make sure the load does not exceed the
output rating.
•
Thermal shutdown (fault code
) •
Allow the unit to cool off.
•
Reduce the load if continuous operation is required.
•
Improve ventilation. Make sure the inverter’s ventilation
openings are not blocked.
•
AC transfer relay has overheated
(during shore power mode).
•
Improve ventilation. Make sure the inverter’s ventilation
grille is not blocked.
•
Reduce the load.
Table 6
Troubleshooting Reference
Problem
Possible Cause
Solution
Freedom HFS IC Owners Guide.book Page 34 Friday, September 11, 2015 2:54 PM
Summary of Contents for 807-1055
Page 2: ...Freedom HFS IC Owners Guide book Page ii Friday September 11 2015 2 54 PM ...
Page 12: ...Freedom HFS IC Owners Guide book Page x Friday September 11 2015 2 54 PM ...
Page 14: ...Freedom HFS IC Owners Guide book Page ii Friday September 11 2015 2 54 PM ...
Page 52: ...Freedom HFS IC Owners Guide book Page 38 Friday September 11 2015 2 54 PM ...
Page 56: ...Freedom HFS IC Owners Guide book Page 42 Friday September 11 2015 2 54 PM ...
Page 57: ...Freedom HFS IC Owners Guide book Page i Friday September 11 2015 2 54 PM ...