background image

8

3. specIfIcAtIons

sIL

entst

Ar

M

AV

Yn

t

AV

Yn

11000D 

M

AV

Yn

11000D 

t

AV

Yn

13000D 

M

AV

Yn

13000D 

t

AV

Yn

COP

 Power 

230V 

(cos

ϕ

=1)

5,5 

kW

2,0 

kW

9,7 

kW

3,3 

kW

11,2 

kW

3,7 

kW

LTP

 Power 

(cos

ϕ

=0,8)

-

6,1 

kW 

/ 7,6 

kV

A

-

9,9 

kW 

/ 12,4 

kV

A

-

11,4 

kW 

/ 14,3 

kV

A

Rated 

Output 

Power

5,5 

kW

5,5 

kW

8,8 

kW 

8,8 

kW 

10 

kW

10 

kW

Noise 

Power 

Level 

(Lwa)

86 

dB

86 

dB

96 

dB

96 

dB

95 

dB

95 

dB

Rated 

Power 

Factor

1

0,8

1

0,8

1

0,8

Rated 

Current

23,9 

A

7,9 

A

38,3 

A

12,9 

A

43,4 

A

14,5 

A

ALtern

Ator

Nominal 

voltage

230 

single

 phase

400 

three 

phases

230 

single

 phase

400 

three 

phases

230 

single

 phase

400 

three 

phases

Alternator 

type

Brushless, 

poles

Brush, 

poles

Voltage 

regulator

AVR

AVR

AVR

AVR

AVR

AVR

Frequency

50 

Hz

Single 

socket 

230V 

IP44 

- 10/16A

1

1

1

1

1

1

Single 

socket 

230V 

- 16A

 (C

ee

)

1

1

1

1

1

1

Single 

socket 

230V 

- 32A

 (C

ee

)

1

-

1

-

1

-

Three 

socket 

400V 

- 3P+T+N 

16A

-

1

-

1

-

1

Access 

for 

remote 

and 

direct 

connection

Serial

Serial

Serial

Serial

Serial

Serial

Voltmeter

Serial

Serial

Serial

Serial

Serial

Serial

Frequencymeter

Serial

Serial

Serial

Serial

Serial

Serial

Hourmeter

Serial

Serial

Serial

Serial

Serial

Serial

enGI

ne

engine 

Model

3TNM72-GWG 

- Y

ANMAR

3TNM68-HG

- Y

ANMAR

3TNM72-HWG 

- Y

ANMAR

engine 

Type

cyl. 

in 

line 

4T

Cooling 

System

Liquid

Maximum 

Output

9,8 

HP

 - 

1500 

rpm

16,1 

HP

 - 

3000 

rpm

19,2 

HP

 - 

3000 

rpm

Piston

 D

isplacemen

t

904 

cm

3

784 

cm

3

904 

cm

3

Fuel

Diesel

Fuel 

Tank 

Capacity

40 

Liters

Autonomy 

at 

3/4 

Load

30 

30

30 

30

17 

00

16 

30

13 

50

13 

30

Starting 

system

eL

eCTRI

CAL

electronic 

Oil 

Sensor

Serial

Frame

Sound 

proof 

canopy 

- Double 

layer 

panel

Dimensions 

LxlxH 

(mm)

1360 

650 

840 

mm

Packaging 

Dimensions 

LxlxH 

(mm)

1380 

650 

860 

mm

Dry 

W

eigh

t

396 

kg

396 

kg

393 

kg

392 

kg

393 

kg

400 

kg

Gross 

W

eight

420 

kg

420 

kg

418 

kg

417 

kg

418 

kg

425 

kg

Summary of Contents for SILENTSTAR 11000D M AVR YN

Page 1: ...Instructions for use GENERATORS GB MODELS SILENTSTAR 7 M AVR YN 7 T AVR YN 11000D M AVR YN 11000D T AVR YN 13000D M AVR YN 13000D T AVR YN MU_02GE_SILENTSTAR_7k_11k_13k_AVR_YN_GB...

Page 2: ...Indicates a strong possibility of severe personal injury loss of life and equipment damage if instructions are not followed CAUTION Indicates a possibility of personal injury or equipment damage if in...

Page 3: ...4 CONTROL PANEL Page 9 5 pre operation check Page 10 6 operating ProcedureS Page 14 7 stopping the generator Page 15 8 oil sensor Page 18 9 wattage information Page 18 10 maintenance schedule Page 20...

Page 4: ...products and this instruction manual Read the operator s instruction manual Stay clear of the hot surface Exhaust gas is poisonous Do not operate in an unventilated room Stop the engine before refueli...

Page 5: ...e polarity U r Rated voltage V Minus negative polarity T max Maximum ambient tempera ture C STOP position of a bistable push control COS Rated power factor ON position of a bistable push control I r R...

Page 6: ...rator has a built in forced air cooling system and may become overheated if it is enclosed If generator has been covered to protect it from the weather during non use be sure to remove it and keep it...

Page 7: ...y hot during and for some time after operation Keep combustible materials well away from generator area Be very careful not to touch any parts of the hot engine especially the muffler area or serious...

Page 8: ...EE 1 1 1 1 1 1 Single socket 230V 32A CEE 1 1 1 Three socket 400V 3P T N 16A 1 1 1 Access for remote and direct connection Serial Serial Serial Serial Serial Serial Voltmeter Serial Serial Serial Seri...

Page 9: ...10 16 A SCHUKO 7 Single phase socket 230V 16A CEE 3 Starting and Control Module Frequencymeter Voltmeter 8 Connection for additional options 4 Key Switch 9 Emergency Stop Button 5 Single phase socket...

Page 10: ...ill with suitable oil 5 Screw again the cap by hand Replace the oil when this one is dirty Oil Capacity Lower Upper Level SILENTSTAR 7 M AVR YN 1 3 2 9 L SILENTSTAR 7 T AVR YN 1 3 2 9 L SILENTSTAR 110...

Page 11: ...etween the lower level written LOW 4 and the upper level written FULL 6 engine not running When the engine will be turned on make sure that the cooling liquid level will be close to the upper level wr...

Page 12: ...iesel Do not forget to place a strainer fuel at the filling side of the tank before filling the tank Make sure the Diesel filter is filled If there is not enough diesel it is necessary to drain the ai...

Page 13: ...before starting engine Fuel leakage from fuel hose etc Leakage of cooling liquid or level of cooling liquid not enough Leakage of oil close to the engine Bolts and nuts for looseness Components for d...

Page 14: ...ust be connected to the earth To ground the generator to the earth connect the grounding lug of the generator to the grounding spike driven into the earth or to the conductor which has been already gr...

Page 15: ...it run for few minutes with no load 1 3 4 2 FONCTION DESCRIPTION 1 Start button In manual mode press to start the generator 2 Auto button Press to change to automatic mode 3 OFF RESET button Press to...

Page 16: ...Battery Voltage 6 3 using eLECTRIc power AC APPLICATION This generator is thoroughly tested and adjusted in the factory If the generator does not produce the specified voltage consult your nearest Wor...

Page 17: ...and have repaired as necessary by Worms dealer or service shop 7 stopping the generator 1 Turn off the power switch of the electric equip ment and unplug the cord from the receptacle of the generator...

Page 18: ...oads such as fluorescent lamps require 1 2 to 2 times the indicated wattage during start up Loads for mercury lamps require 2 to 3 times the indicated wattage during start up Electrical motors require...

Page 19: ...i 130 A maxi 130 A maxi AVR CONTROL Voltage regulating 2 NB Calculations based on the continuous power COP VOLTAGE DROP IN ELECTRIC EXTENSION CORDS When a long electric extension cord is used to conne...

Page 20: ...diesel from the tank Clean the oil of the engine and replace the oil filter Control and clean the blades of the radiator Control the belt of the radiator Adjust the speed control of the engine Clean t...

Page 21: ...drain plug 1 Use fresh and high quality lubricating oil to the specified level If contaminated or deteriorated oil is used or the quantity of the engine oil is not sufficient the engine damage will re...

Page 22: ...owards the outside or from the filtered side towards the not filtered side until it appears no more dust The top of the tube does not have to be in contact with the element see below Then examine care...

Page 23: ...liquid Unscrew the drain cooling liquid cap 1 Screw the cap once the drain completed 11 5 Drain and replacement of the water and diesel filter The water and diesel filter must be changed every 500h C...

Page 24: ...ne Diesel left in the fuel tank will eventually deteriorate making engine starting difficult Change engine oil Check for loose bolts and screws tighten them if necessary Clean generator thoroughly wit...

Page 25: ...on the connected appliance and unplug Check the voltage of the battery Must be over 12V Check if the supply wires of the fuel solenoid and the oil sensor are well connected Reconnect the wires if nec...

Page 26: ...26...

Page 27: ...27...

Page 28: ...l 1 Bd de Strasbourg Bussy Saint Georges 77607 Marne la Vall e Cedex 3 FRANCE Commercial and Spare Parts Service TEL 33 0 1 64 76 29 60 FAX 33 0 1 64 76 29 99 After Sales Service TEL 33 0 1 64 76 29 8...