![Worldwide Construction And Forestry Division 380GLC Operator'S Manual Download Page 191](http://html1.mh-extra.com/html/worldwide-construction-and-forestry-division/380glc/380glc_operators-manual_998038191.webp)
Miscellaneous—Machine
OUT4001,0000238 -19-09MAR17-1/1
ER79617,0000E05 -19-07MAY15-1/1
Using Booster Batteries—24-Volt System
Before boost starting, machine must be properly shut
down to prevent unexpected machine movement when
engine starts.
CAUTION: An explosive gas is produced while
batteries are in use or being charged. Keep flames
or sparks away from the battery area. Make sure
the batteries are charged in a well-ventilated area.
IMPORTANT: The machine electrical system is a
24-volt negative (-) ground. Connect two 12-volt
booster batteries together as shown for 24 volts.
1. Connect one end of the positive (+) cable to the
positive (+) terminal of the machine batteries (A) and
the other end to the positive (+) terminal of the booster
batteries (B).
2. Connect one end of the negative (-) cable to the
negative (-) terminal of the booster batteries. Connect
the other end of the negative (-) cable to the machine
frame as far away from the machine batteries as
possible.
3. Start engine.
T7233JN
—UN—21MA
Y90
Booster Batteries, 2-Battery Application
A—Machine Battery (2 used)
B—Booster Battery (2 used)
4. Immediately after starting engine, disconnect the end
of the negative (-) cable from the machine frame. Then
disconnect the other end of the negative (-) cable from
the negative (-) terminal of the booster batteries.
5. Disconnect positive (+) cable from booster batteries
and machine batteries.
Replacing Batteries
CAUTION: Avoid personal injury from battery acid.
Sulfuric acid in battery electrolyte is poisonous. It
is strong enough to burn skin, eat holes in clothing
and cause blindness if splashed into eyes.
NOTE: Reserve capacity is the time in minutes it
takes a fully charged battery at 26.6°C (80°F)
to drop below 10 volts.
Your machine has two 12-volt batteries (1) with negative
(-) ground connected in series to provide 24-volts.
Use only batteries which meet the following specifications.
Specification
Battery—Cold Cranking
Amps At -18°C (0°F) per
Battery.............................................................................................. 1000
Battery—Minutes
Reserve Capacity At 25
Amps per Battery................................................................................ 320
If one battery in a 24-volt system has failed but the other is
still good, replace the failed battery with one of the same
TX1086967A
—UN—18JAN1
1
Batteries
1— Battery (2 used)
type. For example, replace a failed maintenance-free
battery with a new maintenance-free battery. Different
types of batteries may have different rates of charge. This
difference could overload one of the batteries and cause it
to fail.
4-1-6
092221
PN=191
Summary of Contents for 380GLC
Page 6: ...Introduction Continued on next page TX JDEULA 19 11JUL16 2 3 TX1219046 UN 11JUL16 092221 PN 6...
Page 7: ...Introduction TX JDEULA 19 11JUL16 3 3 TX1219047 UN 14JUL16 092221 PN 7...
Page 9: ...Introduction DX EMISSIONS EPA 19 12DEC12 2 2 TS1721 UN 15JUL13 092221 PN 9...
Page 17: ...Introduction DX EMISSIONS CARB 19 26AUG20 8 8 RG32759 UN 19AUG20 092221 PN 17...
Page 24: ...Introduction 092221 PN 24...
Page 287: ...Index Index 11 092221 PN 11...
Page 288: ...Index Index 12 092221 PN 12...