APPENDIX B:
ADJUSTING THE IMPEDANCE OF ANALOG INPUTS
Default impedance of analog inputs is high.
It can be set to 600 by jumpers.
Before setting the jumpers, make sure that all cables are disconnected. Remove all the screws securing the cover.
Jumper position on a type II board:
J2
J1
High
impedance
600
J1
J2