![Worldcast Systems Ecreso FM 100 W User Manual Download Page 151](http://html1.mh-extra.com/html/worldcast-systems/ecreso-fm-100-w/ecreso-fm-100-w_user-manual_997881151.webp)
ECRESO FM 100/300 W, user manual– 06/2015
Page 151
Head Office : Parc d’activites Kennedy - 20, avenue Neil Armstrong – 33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928 – Fax +33 (0)5 57 928 929 –
www.worldcastsystems.com – [email protected]
A closed link indicates valid information when configuration is as in the following table.
Default jumper position:
Relay
Positions
Contacts
REL_1RT
JUMP2[1 ;2]
NO
REL2_RT
JUMP3[1 ;2]
NO
REL3_RT
JUMP5[1 ;2]
NO
REL4_RT
JUMP1[1 ;2]
NO
REL6_RT
JUMP4[1 ;2]
NO
Jumpers from 1 to 5 (JUMP1 to JUMP5): select the NO or NC contact of the relays.
Switching to local mode (relay 1) prevents remote control: it therefore disables all other relays and commands.
All jumpers are normally open on the GPIO board.