NAME
Access (R/W)
Possible value on the serial port
of the unit
Comments
CONF.DEV.MPX
R/W
00000 à 150.00
Sets the MPX excursion
CONF.DEV.MPXPWR
R/W
-12.7…12.7
Set the MPX power limitation; +128 = disabled
limitation
CONF.DEV.PILOT
R/W
0 to 25.5
Sets the pilot excursion
CONF.DEV.RDS
R/W
0 to 25.5
Sets the RDS excursion
CONF.DEV.SCA
R/W
0 to 25.5
Sets the SCA excursion
CONF.DRIVE.LIMIT
R/W
0 to 25.5
Drive value of the FM limiter in dB
CONF.EXC_TEMP.MAX
R/W
0…99
Sets the triggering threshold for the exciter
temperature alarm
CONF.FADEIN
R/W
0 to 25.5
Sets the fade-in for audio channels in seconds
CONF.FREQ *
R/W
"ON" or "OFF"
Gives the exciter’s working frequency in kHz
CONF.FSK.ID
R/W
[0..9][A…Z][a…z][-]
Code to transmit in Morse, default value: empty
string
CONF.FSK.REP
R/W
0…255
Number of repetitions of CONF.FSK.ID, default
value: 0
CONF.FSK.SHIFT
R/W
[-25…-5][5…25]
Jump in frequency (in kHz), default value: 50
CONF.FSK.SPEED
R/W
0…25
Speed in group number (5 characters base),
default value: 5
CONF.HEAT.MAX
R/W
[0..99]
Sets the triggering threshold for the radiator 1
temperature alarm
CONF.INT_TEMP.MAX **
R/W
0…99
Sets
the
triggering
threshold
for
the
temperature alarm of the internal sensor
CONF.MODE *
R
"LOCAL" or "REMOTE"
Indicates the mode, local or remote. Available in
R/W on amplifiers.
CONF.PHASE.PILOT
R/W
-180..+180
Sets the pilot phase
CONF.PHASE.RDS
R/W
-180..+180
Sets the RDS phase
CONF.PRESSURE.MIN **
R/W
0…2000
Sets the triggering threshold for the pressure
alarm of the internal sensor
CONF.PROBE.PFWD
R/W
[0….9999]
Adjusts the forward power of the RF probe.
Nominal value: 1000.
CONF.PROBE.PREF
R/W
[0….9999]
Adjusts the reflected power of the RF probe.
Nominal value: 1000.
CONF.PSU_TEMP.MAX
R/W
[0..99]
Set the triggering threshold of the PSU
temperature alarm
CONF.PWR *
R/W
[0..999]
Set the Power. from "0" .. "9999"
CONF.PWR_MAX *
R/W
[0..99999]
Set the max power of the transmitter
CONF.PWR. Limited by SYS.PAVL
CONF.RF
R/W
"ON" or "OFF"
ON => Enable RF OFF => Disables RF
CONF.RFPRESENT.MIN *
R/W
[0..999]
STAT.RF (presence RF) triggering threshold;
default value: 0
CONF.SBY *
R
/W
"ON" or "OFF"
Enables the standby mode. Read only for Ecreso
FM
CONF.SFN.DELAY
R/W
0… 5000000.00
SFN delay in µs. Can be set in 1,25 µs
increments
CONF.SFN.STATE
R/W
"ON" or "OFF"
Enables/disables the SFN
CONF.STATE.CLIP
R/W
"ON" or "OFF"
Enables/disables the Hard Clipper
CONF.STATE.LIMIT
R/W
"ON" or "OFF"
Enables/disables the FM limiter
CONF.STATE.MPXPWR
R/W
"ON" or "OFF"
Enables/disables the MPX Power limiter
CONF.VSWR.MAX
*
R/W
XX.X X=[0..9]
Set the VSWR alarm threshold. Use a 3 digit
value. "020" => VSWR = 2. You cannot sent "2"
or "1.4".