Manual 35116
505HT for Pelton Turbines
Woodward
156
Event ID
Description
Explanation
35
Remote Level Signal Fail
A given analog input channel is being used for this
function and its current falls below 2mA or goes above
22mA
36
Remote Fault #1
Discrete Input configured for this function closes (if an
inverted input is used it has to be opened)
37
Remote Fault #2
Discrete Input configured for this function closes (if an
inverted input is used it has to be opened)
38
Remote Fault #3
Discrete Input configured for this function closes (if an
inverted input is used it has to be opened)
39
Remote Fault #4
Discrete Input configured for this function closes (if an
inverted input is used it has to be opened)
40
Remote Fault #5
Discrete Input configured for this function closes (if an
inverted input is used it has to be opened)
41
Remote Fault #6
Discrete Input configured for this function closes (if an
inverted input is used it has to be opened)
42
Nozzle 1 Signal Fault
A given analog input channel is being used for this
function and its current falls below 2mA or goes above
22mA
43
Nozzle 2 Signal Fault
A given analog input channel is being used for this
function and its current falls below 2mA or goes above
22mA
44
Nozzle 3 Signal Fault
A given analog input channel is being used for this
function and its current falls below 2mA or goes above
22mA
45
Nozzle 4 Signal Fault
A given analog input channel is being used for this
function and its current falls below 2mA or goes above
22mA
46
Nozzle 5 Signal Fault
A given analog input channel is being used for this
function and its current falls below 2mA or goes above
22mA
47
Nozzle 6 Signal Fault
A given analog input channel is being used for this
function and its current falls below 2mA or goes above
22mA
48
Major Nozzle1 Mismatch
Nozzle #1 (if used) does not match within the “Major
Mismatch Window” for more than the “Major Mismatch
Delay” time
49
Major Nozzle2 Mismatch
Nozzle #2 (if used) does not match within the “Major
Mismatch Window” for more than the “Major Mismatch
Delay” time
50
Major Nozzle3 Mismatch
Nozzle #3 (if used) does not match within the “Major
Mismatch Window” for more than the “Major Mismatch
Delay” time
51
Major Nozzle4 Mismatch
Nozzle #4 (if used) does not match within the “Major
Mismatch Window” for more than the “Major Mismatch
Delay” time
52
Major Nozzle5 Mismatch
Nozzle #5 (if used) does not match within the “Major
Mismatch Window” for more than the “Major Mismatch
Delay” time
Released
Summary of Contents for 505HT
Page 23: ...Manual 35116 505HT for Pelton Turbines Woodward 21 Figure 2 2 505D Outline Drawing Released...
Page 196: ...Manual 35116 505HT for Pelton Turbines Woodward 194 Figure F 10 Deflector Logic Released...
Page 197: ...Manual 35116 505HT for Pelton Turbines Woodward 195 Revision History New Manual Released...
Page 198: ...Manual 35116 505HT for Pelton Turbines Woodward 196 Declarations Released...