SETUP
PF adjustment (power feed dial calibration)
3
3-12
doc100206
SETUP
To calibrate the power feed dial, press the top button on the left joystick when
„PF Adjustment” has appeared on the display. „PF Min” message should be displayed.
Turn the power feed dial to a point where you want the saw head speed to be 0 (for this
position of the dial the head speed will be 0). Then push the top button on the left joystick
again. The display should now read „PF Max”. Place the dial at a point where you want
the head speed to be maximum and press the top button on the left joystick. If the
programmed range of dial operation is proper, „PF Set OK” will show on the display (the
dial has been calibrated correctly). This means the calibration is complete. If „PF Min/Max
Error” (calibration error) message is displayed, the programmed range of operation is too
small (the minimum speed value is too close to the maximum one) and the calibration
procedure has to be repeated.
The range of dial operation is usually too small if the angle
of dial rotation is lower than 60 degrees.