iVAM1-12G
Page 39
Analog Configuration
Touching the
Analog Config
button in the
System Options Menu
displays the
Analog Config
screen. Contained in this menu is an
Analog Reference
as
illustrated in Figure 2-30. The parameters set on this screen pertain to the
Analog
Input
and
Analog Output
DB25 and XLR connectors on the rear panel of the
iVAM1-12G.
Figure 2-30: Analog Configuration Screen
Analog Config
Cancel
Save
Analog
Reference
<
>
-20 dBFS = +8 dBu
There is only one setting on the
Analog Reference
tab:
1.
Analog Reference
: This setting adjusts the relationship between the
monitored digital signal level and the analog signal level that is output from
both of the DB25 and both of the XLR connectors on the back panel. The
default setting is -20 Dbfs = +8 dBu as shown in Figure 2-30. The range of
possible settings is as follows:
a.
-20 dBFS = +8 dBu
b.
-20 dBFS = 0 dBu
c.
-22 dBFS = +4 dBu
d.
0 dBFS = +15 dBu
e.
-16 dBFS = +4 dBu
f.
-18 dBFS = +4 dBu
g.
-18 dBFS = 0 dBu
h.
-20 dBFS = +4 dBu
Touching
Save
will save any changes made, or touching
Cancel
will return you to
the
System Options
menu without saving.