4-19
Tilt Codes
16-020834-00
Tilt Codes
Refer to
for a definition and possible solution(s) for the tilts displayed by a CPU-NXT
game.
Table 4-4 Tilt Codes .
Display
Definition
Possible Solution(s)
Assert Fail
Message displays:
Machine Fault
Assert:
Assertion=Success
File=\SDG\framework\libslot\bid\t
wentylineproxy.
Function=voidCtwentylineProxy:
activate[]
When doing a RAM clear, be sure to wait for RAM
clear to complete.
Check RAM clear chip.
Check CPU.
Check memory card.
Check software.
Bill Jam Service
Door Open
Bill Acceptor Service Door is
open.
Check the Bill Acceptor Service Door.
Check connections on cherry switch.
Replace switch.
Replace the CPU Board.
Replace Bulkhead.
BillVal Acceptor
Jam
The Bill Acceptor reported that an
inserted bill or ticket is jamming
the acceptor.
Check the Bill Acceptor for jammed bills or tickets.
BillVal Com Error
The Bill Acceptor connector is
disconnected or the Bill Acceptor
head is removed.
Check the Bill Acceptor connection to the
Bulkhead Board.
Check Device settings.
BillVal Device Error
The Bill Acceptor reported that
one of the following components
has failed:
Bill Acceptor
Stack Motor
Feed Motor
RAM
ROM
Replace the Bill Acceptor head.
BillVal Door Open
Bill Acceptor Door is open.
Check the Bill Acceptor Door.
Check connections on cherry switch.
Replace switch.
Replace the CPU Board.
Replace Bulkhead.
BillVal Port Error
An attempt to open, close, read, or
write through the COM port on the
Bulkhead Board has failed. The
Bulkhead Board is not
communicating with the Bill
Acceptor through the COM Port.
Test UART on Bulkhead Board.
Reseat Bill Acceptor and check if communication
is restored.
BillVal Reject Limit
More than ten bills or tickets were
rejected in a row.
Open and close the Main Door.
Clean and calibrate (if applicable).
BillVal Stacker Full
The Cashbox is full.
Replace the full Cashbox.
BillVal Stacker Jam
The Bill Acceptor reports a jam in
the Cashbox.
Check the Cashbox for jammed bills or tickets.
BillVal Stacker Open The Cashbox is removed.
Replace the Cashbox or verify that it is properly
seated.
Check connections on cherry switch
Replace switch.
Replace the CPU Board.
Replace Bulkhead.
BillVal Tamper
The Bill Acceptor reported a
tamper.
Check the Bill Acceptor for evidence of stringing or
other cheating attempts.
CashOut To Host
Failed
Displays when attempting to
cashout to the host and host fails
to respond.
Check host connection.
Closure B
Belly Door was closed.
No action required. Error clears after one game is
played.
Summary of Contents for Bluebird Series
Page 2: ......
Page 12: ...4 List of Figures November 2007 ...
Page 16: ...4 About this Guide General Information October 2007 ...
Page 101: ...5 13 Chapter 5 Exploded Views Block Diagram for BBU AC Power Distribution ...
Page 102: ...5 14 Chapter 5 Exploded Views Block Diagram for BBU Bulkhead with CPU NXT ...
Page 103: ...5 15 Chapter 5 Exploded Views Block Diagram for BBU Bulkhead with CPU NXT ...
Page 104: ......