94
User Manual WMF 1200 S
Technical data
Mains voltage tolerance
range
230 V +6 % and -10 %,
Mains voltage interruption < 50 ms: no interruption of
function
Water supply
(Constant water supply
optional)
3/8 inch hose connector with mains tap, and filter with
0.2 to 0.25 mm mesh size, on site.
Min. 0.2 MPa flow pressure at 2 litres / minute,
max. 0.6 MPa.
Water temperature maximum 35 °C.
The set of hoses provided with the new coffee machine
and/or the new water filter must be used. Do not use
old hoses.
Water quality
For drinking water with carbonate hardness above
5 °dKH, a WMF water filter should be fitted upstream.
Water drain tube
Tube a minimum of DN 19, minimum downward slope
of 2 cm/m
Ambient temperature
+5 °C to m35 °C
(empty the water system in case of frost).
Maximum humidity
80 % relative humidity without condensation.
Do not use device outdoors.
Degree of protection
IP X0
Installation surface /
water spray
The device must be placed and leveled on a horizontal,
sturdy, water-resistant, and heatproof base.
The device must not be cleaned using a water jet.
The device must be installed where it is protected
against water spray. The device must not be located on
a surface that is sprayed or cleaned with a water hose,
steam jets, steam cleaner, or similar devices.