50
Translation of the original operation manual
Airless 270_BAoDB_en_1405 • 0550022 • jw
Rectification of faults
Fault
Possible cause
Remedy
The pump runs irregularly (can be
noticed by dif
ferences in up and
down stroke speeds)and does not
reach the required pressure.
–
The viscosity of the spraying ma-
terial is too high (suction losses).
–
Dilute the spraying material.
–
Use a bigger pump.
–
Suction system leaking (
uctua-
tions in spray jet).
–
Check the packings on all screw
ttings
of the suction pipe or the suction hose,
replace if necessary (see spare parts
list for suction line or direction suction).
–
Bottom valve leaking (pump only
stops in upward stroke when the
spray gun is closed).
–
Unscrew the bottom valve, thorough-
ly clean ball and seat, if necessary
replace ball or valve seat.
–
Piston valve leaking (pump only
stops in downward stroke when
the spray gun is closed).
–
Clean ball and valve in the double
piston, replace ball and valve seat as
necessary
.
–
Bottom or top packing leaking
(wear)
–
Replace the packing.
Material escapes from the over
ow
on the air motor
.
–
Packing worn.
–
Replace the packing.
Note: Do not close of
f the over
ow!