background image

Ed.

003 07 - 14

PLA

 

AIRLESS GUN 

Professional extension

With super fast clean device

With super fast clean device

P A I N T  

S P R A Y I N G  

E Q U I P M E N T

w w w . l a r i u s . e u

GB

PLA SPRAY GUN 250 BAR/MAX

     CODE 

DESCRIPTION

     CODE 

DESCRIPTION

  Airless gun PLA cm 130 swivel M16x1,5
  Airless gun PLA cm 130 swivel 1/4”
  Airless gun PLA cm 180 swivel M16x1,5
  Airless gun PLA cm 180 swivel 1/4”
  Airless gun PLA cm 240 swivel M16x1,5
  Airless gun PLA cm 240 swivel 1/4”

  PLA high pressure cm 240 1/4” + base SFC
  PLA high pressure cm 240 16 x 1,5 + base SFC
  PLA high pressure cm 180 1/4” + base SFC
  PLA high pressure cm 180 16 x 1,5 + base SFC
  PLA high pressure cm 130 1/4” + base SFC
  PLA high pressure cm 130 16 x 1,5 + base SFC

K11421
K11420
K11426
K11425
K11431
K11430

K11446
K11445
K11441
K11440
K11436
K11435

COMPLETE WITH BASE SUPER FAST CLEAN Rif. 18270

AIRLESS GUN PLA 450 BAR/MAX

Summary of Contents for AIRLESS PLA K11435

Page 1: ...cm 180 swivel M16x1 5 Airless gun PLA cm 180 swivel 1 4 Airless gun PLA cm 240 swivel M16x1 5 Airless gun PLA cm 240 swivel 1 4 PLA high pressure cm 240 1 4 base SFC PLA high pressure cm 240 16 x 1 5 base SFC PLA high pressure cm 180 1 4 base SFC PLA high pressure cm 180 16 x 1 5 base SFC PLA high pressure cm 130 1 4 base SFC PLA high pressure cm 130 16 x 1 5 base SFC K11421 K11420 K11426 K11425 K...

Page 2: ...arious parts of the equipment and read the manufacturer s warnings carefully See the Technical Details for the equipment given in the Manual Check the equipment for worn parts once a day If any worn parts are found replace them using ONLY original spare parts Keep children and animals away from work area Comply with all safety standards WARNINGS The table below provides the meaning of the symbols ...

Page 3: ...ecommendations about disposal and recycling process of products in accordance with the environmental regulations Report any danger of electric shock if the warning and presence of live electrical parts has not been indicated Store in a dry place and do not expose to the rain Check that the cables are in good condition Switch off the equipment and discharge any electricity before cleaning or mainta...

Page 4: ...2 English PLA SPRAY GUN PLA AIRLESS GUN A 1A 1 2 3 4 6 8 9 7 8 5 11 12 8 10 15 16 15 18 32 31 29 26 27 28 19 21 22 23 24 25 31 30 20 17 15 16 15 14 5 34 13 35 ...

Page 5: ...d Punch Nut M3 steel Bush Extension punch pla cm 130 Extension punch pla cm 180 Extension punch pla cm 240 Rod for Handgrip Handgrip Articulated tubo ap Supports seal ring Gasket Nut throat packing Nut Guide Shaft Spring Adjustment ring Screw Trigger Trigger Screw cuff M4x6 Trigger pin Safety for hand Ring Handgrip Wheat M4x6 Articulated fully articulated Code Code Descrizione Description 1 1A 2 3...

Page 6: ... 2 1 4 3 6 description B 5 7 4 3 6 1 2 5 4 3 7 Pos Trigger Fingers protection Safety Fitting for high pressure hose Nozzle see table Ground wire connection screw Body super fast clean Description 1 2 3 4 5 6 7 Pos Description ...

Page 7: ...d pump with the solvent apt for the product which is being used SERVICING D Before proceeding with any servicing be sure that the spray gun has no pressure inside and that the product is finished PUNCH SETTING For getting a correct working the punch D2 mo ved by the trigger D7 should open of roughly 3 mm This setting must be done by acting on the nut D3 screwing or unscrewing the punch D2 in the s...

Page 8: ...ssembly of the safety lock E5 it is necessary to unlock it completely clockwise and unscrew the complete part from the gun body Pay attention to the light residual pressure on the main spring E4 it is therefore advisable not to expose any part of your body near to it During the reassembly make sure that the safety nut E5 is locked in order to make the insertion and the assembly in the gun body eas...

Page 9: ...used by the gun casting seekimmediatemedicaladvice specifying the type of the product injected Never undervalue a wound caused by the injection of a fluid Always DISCONNECT THE SUPPLY AND release the pressure in the circuit beforeperforminganycheckorpart replacement of the equipment NEVER MODIFY ANY PART IN THE EQUIP MENT CHECK REGULARLY THE COMPO NENTS OF THE SYSTEM REPLACE THE PARTS DAMAGED OR W...

Page 10: ... hose and accessories with which it can come into contact Never use paints or sol vents containing halogen hydrocarbons as the methylene chloride Iftheseproductscomeintocontactwithaluminium parts can provoke dangerous chemical reactions with risk of corrosion and explosion IFTHE PRODUCTTO BE USED ISTOXIC AVOID INHALATION AND CONTACT BY USING PRO TECTION GLOVES GOGGLES AND PROPER FACE SHIELDS TAKE ...

Page 11: ... 20 SFC 15 40 0 26 0 26 0 35 0 35 0 55 0 55 0 80 0 80 0 80 1 10 1 10 SIZE FLOW L M200 BAR SFC 23 40 SFC 23 60 SFC 25 20 SFC 25 40 SFC 25 60 SFC 27 20 SFC 27 40 SFC 27 60 SFC 27 80 SFC 29 20 SFC 29 40 2 57 2 57 2 90 2 90 2 90 3 50 3 50 3 50 3 50 4 30 4 30 SIZE FLOW L M200 BAR SFC 15 60 SFC 17 20 SFC 17 40 SFC 17 60 SFC 19 20 SFC 19 40 SFC 19 60 SFC 21 20 SFC 21 40 SFC 21 60 SFC 23 20 1 10 1 41 1 41...

Page 12: ... 20 SFC15 40 SFC15 60 SFC17 20 SFC17 40 SFC17 60 SFC19 20 SFC19 40 SFC19 60 SFC21 20 SFC21 40 SFC21 60 SFC23 20 SFC23 40 SFC23 60 SFC25 20 SFC25 40 SFC25 60 SFC27 20 SFC27 40 SFC27 60 SFC27 80 SFC29 20 SFC29 40 SFC29 60 SFC29 80 SFC31 40 SFC31 60 SFC31 80 SFC33 40 SFC33 60 SFC33 80 SFC35 40 SFC37 40 SFC39 40 SFC39 60 SFC39 80 SFC41 40 SFC43 40 SFC43 60 SFC43 80 SFC45 60 SFC47 60 SFC51 60 SFC51 80 ...

Reviews: