36
Translation of the original operation manual
Airless 270_BAoDB_en_1405 • 0550022 • jw
Operation
WARNING
Heating up cleaning agents can cause an explosion. This may
result in serious injury to persons and damage to property.
³
Before flushing the equipment, switch off the material flow
heater (optional) and leave it to cool completely.
³
You will need:
•
at least 5 l of benzine or cleaning agent which is suitable for
the processed material and is recommended by the material
manufacturer, in an open container
•
an additional, conductive collecting vessel for the flushed out
cleaning agent
These containers are not included in the scope of delivery.
1.
Close and secure the spray gun.
2.
Regulate the compressed air pressure controller down all the
way. The pressure gauge has to show 0 bar.
3.
Close the compressed air shut-off valve.
4.
Hold the drain hose into the collecting vessel.
5.
Briefly open the drain valve to release the pressure.
CAUTION
If parts of the equipment (e.g. spray nozzle, material filter on the
spray gun, material hose, high pressure filter, suction strainer,
etc.) are clogged the pressure cannot be fully released. Material
may escape under high pressure and cause injuries when releas-
ing screw fittings.
³
Cover the screw fitting with a rag during releasing to protect
yourself against sudden release of material.
³
Release the screw fittings very carefully and release the
pressure slowly.
³
Remove the obstructions. Note the fault table (Chapter 7
Rectification of faults on page 48).