Translation of the original operation manual
45
Airless 270_BAoDB_en_1405 • 0550022 • jw
Maintenance
1.
Open the release ball
valve (1) and quickly
operate the gun to verify
that the equipment is fully
depressurised.
2.
Use the enclosed hook
spanner to release the
box nut (2) on the cap and
remove the cap (3) of the
high pressure filter.
3.
Loosen the nut (4) and
remove the filter element
(5).
4.
Clean the filter element
with solvent. If the filter
element is damaged it
should be replaced with a
new filter element.
5.
Place the filter element
back on the threaded bolt
(6) and retighten the nut
(4).
6.
Screw the cap (3) with the
box nut (2) onto the high
pressure filter and tighten
it with the hook spanner.
1
2
6
3
Fig. 17
Removing
lter element
5
4
¬
No. Designation
1
Discharge ball valve
2
Retaining nut
3
Cap
4
Nut
5
Filter element
6
Threaded bolt