Maintenance
WARNING
If the pressure in the machine is not relieved when the high
pressure filter is opened, material can escape under very high
pressure and cause serious injuries.
➤
Fully relieve pressure in the machine before opening the high
pressure filter (see chapter 5.5 ‘Relieving the pressure’ on
page 38)
1.
Open the relief valve (4) on the high pressure filter and briefly
trigger the gun to make sure that the machine is absolutely
pressureless.
2.
Release the cap (2) using the hook wrench (1).
3.
Unscrew the nut (6) and remove the filter element (5).
4.
Clean the filter element with solvent. If the filter element has
damage, it should be replaced with a new filter element.
5.
Attach the filter element
onto the stud bolt (3)
again and tighten it with
the nut (6).
6.
Screw the cap (2) onto the
high pressure filter and
tighten the cap with the
hook wrench (1).
No. Designation
1
Hook wrench
2
Cap
3
Stud bolt
4
Relief valve
5
Filter element
6
Nut
Fig. 19: Remove filter element
3
5
2
6
4
1