Original operation manual
39
AirlessPhoenixGX_BA_en_1803 • 0550010-en • jw
Operation
5.6 Work interruption
Lock the spray gun for even the shortest interruptions to work.
Lock the spray gun for short interruptions to work.
Observe the pot life of the materials used, in particular when
using a multi-component material.
The unit must be flushed with the prescribed cleaning agent
within the pot life specified by the manufacturer and be completely
cleaned. Please note:
➤
At higher temperatures, the hardening time shortens.
➤
Let the cleaning agent circulate for some time.
➤
No paint residues may remain in the pump or the filter.
5.7 Decommissioning
For a longer decommissioning, proceed as follows:
1.
Flush the machine as described in chapter 5.3 ‘Flushing’ on
page 36).
2.
Do not completely empty the pump.
As soon as clean solvent runs out of the spray gun or the relief
hose on the high pressure filter, completely reduce the working
pressure (0 bar).
3.
Close the compressed air shut-off valve.
4.
Hold the spray gun sideways against the inner wall of the
collecting vessel and trigger it again.
5.
Hold the relief hose in the collecting vessel and briefly open the
relief valve to relieve the pressure.
The cleaning agent that is still in the machine remains in the
machine until it is restarted, so that the machine parts do not stick
together.
During a longer standstill, fill the machine with a mold oil since the
cleaning agent evaporates over time.