cyber
®
simco
®
drive 2 operating manual
en-40
5022-D057946
Revision: 02
6.6.11 X8: Digital I/O
An external power supply must be connected to supply the digital outputs.
The digital outputs are galvanically isolated from the logic and power of the
drive amplifier.
The digital outputs are short-circuit proof.
Figure
Pin
no.
Signal
Function
Input / output
1
VCC24
Digital output
supply
Input
2
GND
Ground
reference
3
DIN1
Digital input 1
Input
4
DIN2
Digital input 2
Input
5
DIN3
Digital input 3
Input
6
DIN4
Digital input 4
Input
7
DOUT1
Digital output 1
Output
8
DOUT2
Digital output 2
Output
Plug type on drive amplifier: Dinkle 0225-3708L 8-pin
Connection Feature
Unit
Minimum
value
Nominal
value
Maximum
value
DINx
Input voltage
V DC
20
24
28
Input current
mA DC
3
4
5
Input resistance
kOhm
5.6
Sample time
msec
1
GND
Ground reference
DOUTx
Output voltage
V DC
18
24
26
Output current
mA DC
40
Output resistance
kOhm
1
1.5
2
Refresh rate
Hz
1
VCC24
Voltage
V DC
20
24
28
Current
mA DC
80
GND