cyber
®
simco
®
drive 2 operating manual
Revision: 02
5022-D057946
en-39
de
utsch
english
fra
nçais
ita
lia
no
es
pa
ñol
日本語
6.6.9 X6/X7: Fieldbus interface CANopen
The CAN ground reference is identical to the logic ground reference.
The CAN signals are galvanically isolated from the power of the drive amplifier.
Figure
Pin
no.
Signal
Function
J1
CAN_H
CAN High
J2
CAN_L
CAN Low
J3
CAN_GND
CAN ground
reference
J4
N.C.
J5
N.C.
J6
N.C.
J7
N.C.
J8
N.C.
Plug type on drive amplifier: LAN RJ45
Connection
Feature
Unit
Minimum
value
Nominal
value
Maximum
value
Baud rate
kbaud
100
500
1000
6.6.10 X6/X7:Fieldbus interface EtherCat, PROFINET, EtherNet/IP and SERCOS III
The signals are galvanically isolated from the logic and power of the drive.
Figure
Pin
no.
Signal
name
Function
J1
RD+
Receive Data +
J2
RD-
Receive Data -
J3
TD+
Transmit Data +
J4
N.C.
J5
N.C.
J6
TD-
Transmit Data -
J7
N.C.
J8
N.C.
Plug type on drive amplifier: LAN RJ45
Connection
Feature
Unit
Minimum
value
Nominal
value
Maximum
value
Transmission
speed
MBit/s
100
X7
Fieldbus OUT
X6
Fieldbus IN
X7
Feldbus OUT
X6
Feldbus IN