3.5 Requirements for cables and wiring
In general, use high-quality, shielded motor and encoder cables to avoid EMC
problems.
Wire type
Maximum
length
Capacitance
per unit length
Core to shield
Motor wire
20 m
< 150 pF/m
Encoder line
20 m
< 120 pF/m
Resolver line
20 m
< 120 pF/m
Table 4: Cabling and wiring
Further requirements regarding TÜV NRTL are listed in chapter 2.1.2
”.
3.6 STO safety function
The STO safety function (
S
afe
T
orque
O
ff) is used for safe torque shutdown and to reliably
protect drives from restarting. The drive amplifier is fitted with a two-channel STO function
as standard in the basic model.
Instructions for the STO safety function can be found in the appendix
(see chapter 10
“STO safety function instructions”).