5 Mechanical installation
5.1 Safety instructions
For the mechanical installation, the ESD information must be observed.
The drive amplifier (control cabinet version) must be protected from fog, water and
penetration of metallic dust in the electrical cabinet.
The drive amplifier must be checked for mechanical damage before installation.
Only install flawless drive amplifiers.
During installation in a control cabinet, sufficient ventilation must be provided.
The operation of drive amplifiers exposed to condensation is not permitted.
The drive system may only be assembled with the power
disconnected.
Systems that are electrically connected must be properly secured so
they cannot be switched back on and warning signs must be put up.
Assembly may only be performed by trained personnel.
5.2 Device version IP65 decentral SIM20xxD-FC...
5.2.1 IP65 dimensions
Mechanical data
Weight [g]
620
Length [mm]
205.97
Width [mm]
62
Depth without plug [mm]
55.55
Depth with plug [mm]
70.33
Table 5: IP65 dimensions