VoiceAlert
2
User Manual
Code 17 – Set Siren, Wired Zone, Telephone Line Tamper, and
Arming / Alarming Delay Buzzer
Prerequisite for basic VA
2
operation:
NO
Reason for Configuration:
To ensure correct siren function and tamper control.
Background info:
VA
2
has four wired zones. These can be wired as either normally open and or normally
closed connections. built-in siren when triggered. The required zones need to be entered after the
configuration code [16]. Wired Zones 1 to 4 are entered as “1, 2, 3, 4”. Wireless Zones can be entered as
single entry “9” for all wireless zones.
Function Options:
1. Set Siren to sound / not sound when alarming: (0) sound, (1) no sound
2. Set wired zones as either normally open or normally closed type (When wired as normally closed
type, 2k2 resistors must be used in line with the series connection between the zone terminals and
GND): (0) normally closed, (1) normally open
3. Activate tamper function for telephone line: (0) activated, (1) deactivated.
4. Activate built-in buzzer for alerting when arming delay is in progress and for when alarming (entry)
delay is activated. Set to (0) no buzzer alerts, (1) buzzer active during arming delay but not for
alarming delay (2) buzzer active for alarming delay but not for arming delay, (3) buzzer for both
arming delay and for alarming delay.
Procedure - Set Function 1, 2, 3 and 4
(e.g. siren to sound when alarming, wired zones set as normally
closed, telephone line tamper active, and buzzer to sound for both arming delay and alarming delay)
:
•
Press
Return
(Inverted Arrow)
•
Press
PRG
•
Enter
17
•
Press
OK
•
Enter 0003
•
Press
OK
•
LCD will Display as above
•
Press
Return
to exit
Related configuration codes
(You may need to set the following related configurations):
•
29
•
30
Code 18 – Set Panel Date and Time
Prerequisite for basic VA
2
operation:
NO.
Reason for Configuration:
Time arming / disarming of zones, alarm clock function and storage of alarm
and arming log events.
Copyright InFocus Trading 111 cc, 2009